Joint with cyclic movements should have a width: depth ratio of 2:1 and designed so as total movement does not exceed the 25% MAF related to the joint width.Sealant depth shall not exceed joint width Minimum sealant depth recommended5mm for metals, glass and other impervious surfaces.10mm for all porous surfaces.20mm for joints exposed to traffic and hydrostatic pressures.5mm below flush for joint