In the situation where chemicals such as TEOS and Ozone are employed for thermal oxide deposition, an increase in the showerhead temperature typically reduces the likelihood of liquid condensation if a liquid chemical is used, and will thereafter favor the delivery of TEOS. However, higher temperatures experienced within the showerhead typically reduces the Ozone concentration since the half-life